Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38335120

RESUMO

Electrical biosensors, including transistor-based devices (i.e., BioFETs), have the potential to offer versatile biomarker detection in a simple, low-cost, scalable, and point-of-care manner. Semiconducting carbon nanotubes (CNTs) are among the most explored nanomaterial candidates for BioFETs due to their high electrical sensitivity and compatibility with diverse fabrication approaches. However, when operating in solutions at biologically relevant ionic strengths, CNT-based BioFETs suffer from debilitating levels of signal drift and charge screening, which are often unaccounted for or sidestepped (but not addressed) by testing in diluted solutions. In this work, we present an ultrasensitive CNT-based BioFET called the D4-TFT, an immunoassay with an electrical readout, which overcomes charge screening and drift-related limitations of BioFETs. In high ionic strength solution (1X PBS), the D4-TFT repeatedly and stably detects subfemtomolar biomarker concentrations in a point-of-care form factor by increasing the sensing distance in solution (Debye length) and mitigating signal drift effects. Debye length screening and biofouling effects are overcome using a poly(ethylene glycol)-like polymer brush interface (POEGMA) above the device into which antibodies are printed. Simultaneous testing of a control device having no antibodies printed over the CNT channel confirms successful detection of the target biomarker via an on-current shift caused by antibody sandwich formation. Drift in the target signal is mitigated by a combination of: (1) maximizing sensitivity by appropriate passivation alongside the polymer brush coating; (2) using a stable electrical testing configuration; and (3) enforcing a rigorous testing methodology that relies on infrequent DC sweeps rather than static or AC measurements. These improvements are realized in a relatively simple device using printed CNTs and antibodies for a low-cost, versatile platform for the ongoing pursuit of point-of-care BioFETs.

2.
ACS Omega ; 8(1): 1597-1605, 2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36643551

RESUMO

Printing technologies offer an attractive means for producing low-cost surface-enhanced Raman spectroscopy (SERS) substrates with high-throughput methods. The development of these substrates is especially important for field-deployable detection of environmental contaminants. Toward this end, we demonstrate SERS-based substrates fabricated through aerosol jet printing of silver nanoparticles and graphene inks on Kapton films. Our printed arrays exhibited measurable intensities for fluorescein and rhodamine dyes down to concentrations of 10-7 M, with the highest SERS intensities obtained for four print passes of Ag nanoparticles. The substrates also exhibited an excellent shelf life, with little reduction in fluorescein intensities after 9 months of shelf storage. We also demonstrated the capability of our substrates to sense perfluoroalkyl substances (PFAS), the so-called forever chemicals that resist degradation due to their strong C-F bonds and persist in the environment. Interestingly, the addition of graphene to the Ag nanoparticles greatly enhanced the SERS intensity of the perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) molecules under basic conditions (pH ∼ 9) compared to that of fluorescein and rhodamine. We were able to successfully detect SERS spectra from nano- and picomolar (∼0.4 ppt) concentrations of PFOA and PFOS, respectively, demonstrating the viability of deploying our SERS sensors in the environment for the ultrasensitive detection of contaminants.

3.
ACS Appl Nano Mater ; 5(10): 15865-15874, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36815139

RESUMO

Interest in point-of-care diagnostics has led to increasing demand for the development of nanomaterial-based electronic biosensors such as biosensor field-effect transistors (BioFETs) due to their inherent simplicity, sensitivity, and scalability. The utility of BioFETs, which use electrical transduction to detect biological signals, is directly dependent upon their electrical stability in detection-relevant environments. BioFET device structures vary substantially, especially in electrode passivation modalities. Improper passivation of electronic components in ionic solutions can lead to excessive leakage currents and signal drift, thus presenting a hinderance to signal detectability. Here, we harness the sensitivity of nanomaterials to study the effects of various passivation strategies on the performance and stability of a transistor-based biosensing platform based on aerosol-jet-printed carbon nanotube thin-film transistors. Specifically, non-passivated devices were compared to devices passivated with photoresist (SU-8), dielectric (HfO2), or photoresist + dielectric (SU-8 followed by HfO2) and were evaluated primarily by initial performance metrics, large-scale device yield, and stability throughout long-duration cycling in phosphate buffered saline. We find that all three passivation conditions result in improved device performance compared to non-passivated devices, with the photoresist + dielectric strategy providing the lowest average leakage current in solution (~2 nA). Notably, the photoresist + dielectric strategy also results in the greatest yield of BioFET devices meeting our selected performance criteria on a wafer scale (~90%), the highest long-term stability in solution (<0.01% change in on-current), and the best average on/off-current ratio (~104), hysteresis (~32 mV), and subthreshold swing (~192 mV/decade). This passivation schema has the potential to pave the path toward a truly high-yield, stable, and robust electrical biosensing platform.

5.
NPJ Breast Cancer ; 7(1): 85, 2021 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-34215753

RESUMO

Management of breast cancer in limited-resource settings is hindered by a lack of low-cost, logistically sustainable approaches toward molecular and cellular diagnostic pathology services that are needed to guide therapy. To address these limitations, we have developed a multimodal cellphone-based platform-the EpiView-D4-that can evaluate both cellular morphology and molecular expression of clinically relevant biomarkers directly from fine-needle aspiration (FNA) of breast tissue specimens within 1 h. The EpiView-D4 is comprised of two components: (1) an immunodiagnostic chip built upon a "non-fouling" polymer brush-coating (the "D4") which quantifies expression of protein biomarkers directly from crude cell lysates, and (2) a custom cellphone-based optical microscope ("EpiView") designed for imaging cytology preparations and D4 assay readout. As a proof-of-concept, we used the EpiView-D4 for assessment of human epidermal growth factor receptor-2 (HER2) expression and validated the performance using cancer cell lines, animal models, and human tissue specimens. We found that FNA cytology specimens (prepared in less than 5 min with rapid staining kits) imaged by the EpiView-D4 were adequate for assessment of lesional cellularity and tumor content. We also found our device could reliably distinguish between HER2 expression levels across multiple different cell lines and animal xenografts. In a pilot study with human tissue (n = 19), we were able to accurately categorize HER2-negative and HER2-positve tumors from FNA specimens. Taken together, the EpiView-D4 offers a promising alternative to invasive-and often unavailable-pathology services and may enable the democratization of effective breast cancer management in limited-resource settings.

6.
ACS Appl Mater Interfaces ; 9(6): 5522-5529, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28117566

RESUMO

Advances in electronics and life sciences have generated interest in "lab-on-a-chip" systems utilizing complementary metal oxide semiconductor (CMOS) circuitry for low-power, portable, and cost-effective biosensing platforms. Here, we present a simple and reliable approach for coating "high-κ" metal oxide dielectric materials with "non-fouling" (protein- and cell-resistant) poly(oligo(ethylene glycol) methyl ether methacrylate (POEGMA) polymer brushes as biointerfacial coatings to improve their relevance for biosensing applications utilizing advanced electronic components. By using a surface-initiated "grafting from" strategy, POEGMA films were reliably grown on each material, as confirmed by ellipsometric measurements and X-ray photoelectron spectroscopy (XPS) analysis. The electrical behavior of these POEGMA films was also studied to determine the potential impact on surrounding electronic devices, yielding information on relative permittivity and breakdown field for POEGMA in both dry and hydrated states. We show that the incorporation of POEGMA coatings significantly reduced levels of nonspecific protein adsorption compared to uncoated high-κ dielectric oxide surfaces as shown by protein resistance assays. These attributes, combined with the robust dielectric properties of POEGMA brushes on high-κ surfaces open the way to incorporate this protein and cell resistant polymer interface into CMOS devices for biomolecular detection in a complex liquid milieu.

7.
Lab Chip ; 16(21): 4181-4188, 2016 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-27714014

RESUMO

The ability to direct and sort individual biological and non-biological particles into spatially addressable locations is fundamentally important to the emerging field of single cell biology. Towards this goal, we demonstrate a new class of magnetophoretic transistors, which can switch single magnetically labeled cells and magnetic beads between different paths in a microfluidic chamber. Compared with prior work on magnetophoretic transistors driven by a two-dimensional in-plane rotating field, the addition of a vertical magnetic field bias provides significant advantages in preventing the formation of particle clumps and in better replicating the operating principles of circuits in general. However, the three-dimensional driving field requires a complete redesign of the magnetic track geometry and switching electrodes. We have solved this problem by developing several types of transistor geometries which can switch particles between two different tracks by either presenting a local energy barrier or by repelling magnetic objects away from a given track, hereby denoted as "barrier" and "repulsion" transistors, respectively. For both types of transistors, we observe complete switching of magnetic objects with currents of ∼40 mA, which is consistent over a range of particle sizes (8-15 µm). The switching efficiency was also tested at various magnetic field strengths (50-90 Oe) and driving frequencies (0.1-0.6 Hz); however, we again found that the device performance only weakly depended on these parameters. These findings support the use of these novel transistor geometries to form circuit architectures in which cells can be placed in defined locations and retrieved on demand.


Assuntos
Eletroforese/instrumentação , Campos Magnéticos , Transistores Eletrônicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...